On the job in Jenks




At a glance
- Where: Jenks, OK 74037
- Completed: November 12, 2026
- Services: Gas line repair · Kitchen & bathroom plumbing
- Licensed: Oklahoma plumbing license #035596
What the homeowner wanted
The homeowner in Jenks ZIP 74037 was getting a gas range, but the kitchen had no gas line for one. She called for an estimate and, if she approved, wanted the work done on the same visit. She approved it, and Michael, Josh and Kagen ran the line that morning.
A spare port in the attic
The first question on a new gas line is where to tap in. Running a separate line from the meter is a big job. Tapping the nearest existing pipe is only right if that pipe is big enough for what is already on it plus the new appliance.
This house made it easy. At the top of the stairs in the attic there was a gas manifold, a distribution block with several outlets feeding different appliances through yellow flexible gas tubing. One half-inch port on that manifold had been plugged and never used. That spare port is exactly what a builder leaves for a future appliance, and it was the right size for a range line.
Running the line
The crew shut the gas off to the manifold and unthreaded the plug from the spare port. From there they ran 50 feet of new half-inch CounterStrike CSST, a corrugated stainless steel gas tubing with a black jacket made to resist damage from lightning, across the attic and down inside the wall behind where the stove sits.
Where the line came down through the framing, they protected it with a nail plate so a future nail or screw cannot puncture it, and they used talon straps to secure the tubing along its run. At the kitchen end they installed a CSST termination plate, a male adapter, a black street 90 and a gas stop, then capped it so it is ready for the range connector.
Then the gas went back on at the manifold. Shutting off the manifold had put out the water heater pilot, so the crew relit the water heater. Last, they sprayed every new connection with leak detector solution, at the manifold and at the stub-out. No bubbles, no leaks, everything working.
Why CSST and why the nail plate
CSST is flexible, which matters in an attic. A run like this one, across trusses and down a wall cavity, would take many joints in black iron pipe. Each joint is a place a leak could start. Flexible tubing makes the run in long continuous lengths, with fittings only at the ends.
The trade-off is that CSST is thinner than iron pipe, so it has to be protected wherever it passes close to the face of a stud. That is what the nail plate is for. Black-jacketed CSST like CounterStrike is also designed to handle electrical energy from a nearby lightning strike better than older yellow tubing, which is a real concern in Oklahoma.
Ready for the new range
When the crew left, there was a new capped gas stop behind the range, the gas manifold was back on, the water heater was relit, and every connection had been leak-tested. The homeowner's installer or delivery crew can now connect the range with a flexible appliance connector.
This installation carries a one-year parts and labor warranty.
Questions to answer before the range arrives
A few questions save trouble on delivery day. Where is the nearest gas supply, and what size is it? Here the answer was a spare half-inch port on a manifold in the attic, close to the top of the stairs. In other homes the nearest gas is a water heater line in the garage or a furnace branch in a crawl space, and the route changes.
Where will the range sit, and where does the gas stop need to come out of the wall? The stub-out has to land where the range's connector can reach it without kinking and where the range can still slide back flush. Measure from the range's spec sheet before the line is run.
Is there an outlet behind the range? Most gas ranges still need 120-volt power for the igniters and controls. That is an electrician's job, not ours, but it is easy to forget until the range is sitting in the kitchen.
Last, plan to relight anything that was shut off. On this job the water heater pilot went out when the manifold was closed, and the crew relit it before leaving.
One more point on sizing. A half-inch line is the common size for a household range, but the run length and what else is on the same supply both matter. A long run or a manifold already feeding a furnace and a water heater may call for a larger line. Here, the builder had already planned for it: a dedicated half-inch port on a manifold sized to carry it. That made the tap simple and kept the new line from robbing gas from the appliances already on the system.
What this means for your home
Switching from electric to gas cooking is usually simpler than people expect, as long as there is a sensible place to tap in. Before you buy the range, have a plumber look at your attic or crawl space. A spare manifold port like the one in this Jenks home can save a lot of work.
Do not let anyone connect a new appliance without leak-testing the new joints. Spray-testing every connection is the minimum. See gas line repair in Tulsa for more.
Services on this job: Gas line repair · Kitchen & bathroom plumbing · Plumber in Jenks · How our pricing works · All job stories
Straight Answers
Can you add a gas line for a new range if the kitchen never had one?
Usually, yes. In this Jenks home we tapped a spare half-inch port on the attic gas manifold, ran new CSST down the wall behind the stove to a capped gas stop and leak-tested every connection.