Emergency & LeaksEmergency PlumbingWater Leak RepairSlab Leak DetectionWhole-Home RepipingGas Line RepairDrains & SewerDrain Cleaning & Sewer RepairMain Line Sewer CleaningSewer Camera InspectionGarbage DisposalWater Heaters & Water SystemsWater Heater RepairWater Heater InstallationTankless Water HeatersWater FiltrationPressure Regulator (PRV)Fixtures & MoreToiletsFaucets & FixturesShower & Tub ValvesKitchen & Bath InstallsOutdoor Hydrants & SpigotsCommercial PlumbingInspection & MaintenanceJob Stories About Reviews FAQ Contact Book Now Call (918) 891-1737 Book Online Text Us Request Service
Acts of Service Plumbing job story · Broken Arrow, OK 74014 · Completed September 9, 2026

Replacing a Water Pressure Reducing Valve in Broken Arrow

Job photos

Before and after

Before the repair: Replacing a Water Pressure Reducing Valve in Broken Arrow, photographed on the job by Acts of Service Plumbing
Before
After the repair: Replacing a Water Pressure Reducing Valve in Broken Arrow, finished work by Acts of Service Plumbing
After
Closet location of the pressure-regulator work in Broken Arrow, Oklahoma — Acts of Service Plumbing job photo
Closet location of the pressure-regulator work
The problem

What the homeowner called about

Homeowners in Broken Arrow noticed a water hammer sound and needed a plumbing diagnosis for their water pressure system.

Diagnosis

What our plumber found

Our crew diagnosed the issue and determined the existing pressure reducing valve needed to be replaced.

The fix

How we fixed it

Our plumber replaced the old valve using a new three-quarter-inch PRV double-sided union, along with propress adapters, expansion adapters, expansion tees, expansion nineties, an expansion ball valve, and male expansion adapters.

On the job

The closet valve and the connection plan

Casey and Jared were assigned to this Broken Arrow visit. The call was to diagnose water hammer, and the pressure reducing valve was located in the master closet. The work description identifies the existing valve as starting to fail and hammer. The customer gave Casey verbal approval for the replacement. There is no recorded before-and-after pressure reading in this job, so we are not attaching a guessed pressure number to the repair.

The replacement scope described two possible connection paths. First, the plumber would try to unthread and remove the existing PRV. If the new valve lined up and used the same thread pattern, it could be installed in the old valve's position. The union threads needed to fit correctly. This was a fit-and-connection check, not simply a matter of choosing a valve that looked similar from outside the wall.

If the new valve was different in size, the approved description allowed for rebuilding the manifold for the shutoff and PRV. That alternate scope involved cutting out the old pressure regulator and the old shutoff valve, then using suitable fittings to install both replacements. The description presented that as a conditional route with additional work, not as proof that every piece of the manifold ultimately had to be rebuilt.

The parts notes identify a three-quarter-inch, double-sided-union PRV. The list also includes two three-quarter-inch press-to-expansion adapters and two half-inch press-to-expansion adapters. Two three-quarter-by-half-by-three-quarter expansion tees were listed, along with one half-inch expansion elbow and four three-quarter-inch expansion elbows. A three-quarter-inch expansion ball valve and two three-quarter-inch male expansion adapters were also included in the material notes.

Those sizes help explain why the connection plan mattered. The work involved the regulator, its union connections, the shutoff arrangement and transitions between existing plumbing and expansion fittings. It was not a faucet cartridge repair or a replacement of all the water piping in the home. The job-specific material notes describe the components prepared for work at this one valve location.

The test sequence in the scope was to restore water to the house and check for leaks and proper operation after installing the new valve. If the manifold-rebuild route was needed and the connections passed those checks, the description also called for putting the drywall back in place. We are keeping that conditional wording because the description does not identify which connection route was used in the final installation.

Takeaway

What this means for your home

A failing pressure reducing valve can cause water hammer noises and improper water pressure throughout your home plumbing system.

More about this service · Plumber in Broken Arrow · How our pricing works · All job stories

Questions

Straight Answers

What causes water hammer noises in the plumbing system?

Water hammer is often caused by pressure issues or a failing pressure reducing valve that needs replacement.

How do you know if a PRV valve needs to be replaced?

Our plumber can diagnose your system to determine if a worn-out PRV valve is causing banging pipes or improper water pressure.

What is included when replacing a water pressure reducing valve?

The replacement process involves installing a new PRV valve along with matching expansion fittings and unions to secure the connection.

Acts of Service Plumbing service van at the shop
Acts of Service Plumbing

Real Techs. Real Answers.

Every job on this page is answered the way our own crew describes it — no scripts, no upsells.

Call Acts of Service Plumbing

Open 24 hours Monday through Saturday · Closed Sunday